They combine advantages of electronic controllers with digital circuit “intelligence”. A possibility to program temperature in 24h and a week cycle. A possibility to read out on a LCD such data as: a room real temperature, previously programmed comfort and economic temperatures, a heating system operating time, a program number and its graphical image. Selected models have an adaptation function: the temperature controller “calculates” itself the heating switching off moment to reach a desired temperature at a programmed time. Load up to 3600 W. They can be surface or flush mounted.
type | Elektra MWD5 WiFi | Elektra MCD5 |
floor sensor | + | + |
air sensor | + | + |
floor protecting sensor (°C) | from +10 to +40 | from +10 to +40 |
wireless controll (WiFi) | + | – |
installation | flush | flush |
supply (V) | 230 | 230 |
control range (°C) | from +5 to +40 | from +5 to +40 |
temperature setback (°C) | from +5 to +40 | from +5 to +40 |
open window detection | + | + |
max. load (W) | 3600 | 3600 |
switch | 2-pole | 2-pole |
hysteresis (K) | PI* | PI* |
ingress protection (IP) | 21 | 21 |
dimensions (H x W x D) (mm) | 82 x 82 x 40 | 82 x 82 x 40 |
* adaptative system (proportional-integral) adjusting the deviation to the set temperature depending on the duration of the temperature’s increase or decrease. Due to this feature the controller’s operational characteristics is self-adjusted to ambient conditions, in real time.
type | Elektra ELR20 | Elektra ELR30 WiFi |
floor sensor | + | + |
air sensor | + | + |
floor protecting sensor (°C) | from +16 to +60 | from +16 to +60 |
wireless controll (WiFi) | – | + |
installation | flush | flush |
supply (V) | 230 | 230 |
control range (°C) | from +5 to +90 | from +5 to +90 |
temperature setback (°C) | from +5 to +90 | from +5 to +90 |
open window detection | + | + |
max. load (W) | 3600 | 3600 |
switch | 2-pole | – |
hysteresis (K) | 0,5 ÷ 10 | 0,5 ÷ 10 |
ingress protection (IP) | 20 | 20 |
dimensions (H x W x D) (mm) | 90 x 86 x 45 | 86 x 86 x 46 mm |